Impact of contact lens material and design on the ocular surface.
2018
BACKGROUND: To evaluate the impact on the ocular surface of a daily disposable hydrogel contact lens with high water content compared with two silicone hydrogel daily disposable lenses of lower water content. METHODS: The hydrogel lens assessed was made from nesofilcon A and the silicone hydrogel lenses were made of delefilcon A and stenfilcon A. Contact lens thickness was measured to assess material stability during daily wear, and ocular surface parameters such as tear film osmolarity, tear meniscus area and central corneal thickness were also assessed. Optical quality was analysed for all cases by means of wavefront aberrometry. RESULTS: The nesofilcon A was shown to be the thinnest lens…
Postoperative Repositioning of Inverted Descemet Membrane Endothelial Keratoplasty Grafts
2019
Item does not contain fulltext PURPOSE: To present 4 cases of postoperative repositioning of inverted grafts after Descemet membrane endothelial keratoplasty (DMEK). METHODS: Retrospective case reports of 4 patients presenting with subtotal to total graft detachment after DMEK, most probably owing to upside-down graft positioning. Graft repositioning was performed 1 to 14 days after initial DMEK surgery. In 3 cases (cases 1, 3, and 4), repositioning was performed without removing the graft from the anterior chamber (AC), whereas for case 2, the graft had to be removed from the AC to attain correct graft orientation. RESULTS: In all 4 cases, the initially upside-down DMEK grafts could be suc…
Assessment of induced corneal hypoxia in diabetic patients
2002
Comparative Study Address correspondence and reprint requests to Dr. C. Creuzot-Garcher, Service d'Ophtalmologie, CHU, Hopital Général, 3 Rue du Faubourg Raines, BP 1519, 21033 Dijon, France. E-mail: Catherine.creuzot-garcher@chu-dijon.fr; To assess the control of corneal hydration in patients with diabetes during a contact lens-induced hypoxia. Corneal stress was induced in 15 patients with diabetes and 23 healthy patients by having them wear contact lenses for 2 hours. Pachymetries were measured and corneal parameters (percentage recovery per hour [PRPH], time for deswelling [T99%] and induced swelling [IS]) were calculated. In the mean time, tears were collected to assess the activity of…
Application principles of excimer lasers in ophthalmology
2010
Abstract Excimer lasers (193 nm) can be used for photoablation of the human cornea due to their specific physical characteristics. This laser is applied in corneal refractive surgery for the targeted removal of corneal tissue for the purpose of correcting refractive errors. This article provides a short overview of the scientific development of excimer lasers for use in ophthalmic surgery and of the range of applications of these tools.
Modulation of central corneal thickness by various riboflavin eyedrop compositions in porcine corneas
2012
Purpose To evaluate the modulatory effect of various riboflavin 0.1% and 0.2% compositions on the central corneal thickness (CCT) in fresh porcine corneas. Setting Department of Ophthalmology, Johannes Gutenberg University of Mainz, Mainz, Germany. Design Experimental study. Methods The CCT in freshly enucleated porcine globes was measured by ultrasound pachymetry before and after (if applicable) deepithelialization and every 10 minutes thereafter during 120 minutes of eyedrop application. In Groups 1 and 2 (controls), no eyedrops were applied. In Groups 3 and 4, isotonic riboflavin eyedrops were used. In Groups 5 to 9, hypotonic riboflavin eyedrops were given. In Groups 10 and 11, preparat…
Acute endothelial failure after cosmetic iris implants (NewIris®)
2011
We report a case of an acute endothelial failure after the implantation of a new cosmetic, colored, artificial iris diaphragm implant called NewIris(®). A 21-year-old woman came to us complaining of progressive loss of vision and pain after NewIris lenses had been implanted. Decreased visual acuity, corneal edema, and increased intraocular pressure in both eyes appeared only 3 weeks after the surgery. The lenses were removed as soon as possible but had already severely affected the endothelial cell count. NewIris implants are an alternative to cosmetic contact lenses, but they are not as safe as other phakic anterior chamber intraocular lenses, nor are they a good option for the patient.